{"id":370,"date":"2020-11-24T13:06:06","date_gmt":"2020-11-24T16:06:06","guid":{"rendered":"https:\/\/gnrambiental.com.br\/noticias\/?p=370"},"modified":"2025-12-15T17:08:07","modified_gmt":"2025-12-15T20:08:07","slug":"nho-11-avaliacao-dos-niveis-de-iluminamento-em-ambientes-internos-de-trabalho","status":"publish","type":"post","link":"https:\/\/gnrambiental.com.br\/noticias\/nho-11-avaliacao-dos-niveis-de-iluminamento-em-ambientes-internos-de-trabalho\/","title":{"rendered":"NHO 11 \u2013 Avalia\u00e7\u00e3o dos N\u00edveis de Iluminamento em Ambientes Internos de Trabalho"},"content":{"rendered":"<p data-start=\"256\" data-end=\"559\">A <strong data-start=\"258\" data-end=\"341\">NHO 11 \u2013 Avalia\u00e7\u00e3o dos n\u00edveis de iluminamento em ambientes internos de trabalho<\/strong> \u00e9 a norma t\u00e9cnica da <strong data-start=\"363\" data-end=\"378\">Fundacentro<\/strong> que estabelece crit\u00e9rios e procedimentos para avaliar a <strong data-start=\"435\" data-end=\"484\">ilumina\u00e7\u00e3o adequada nos ambientes de trabalho<\/strong>, com foco em <strong data-start=\"498\" data-end=\"558\">seguran\u00e7a, sa\u00fade ocupacional e desempenho das atividades<\/strong>.<\/p>\n<p data-start=\"561\" data-end=\"767\">Essa norma \u00e9 amplamente utilizada em <strong data-start=\"598\" data-end=\"635\">avalia\u00e7\u00f5es de higiene ocupacional<\/strong>, <strong data-start=\"637\" data-end=\"656\">laudos t\u00e9cnicos<\/strong>, <strong data-start=\"658\" data-end=\"672\">auditorias<\/strong>, <strong data-start=\"674\" data-end=\"699\">per\u00edcias trabalhistas<\/strong> e na gest\u00e3o de riscos ocupacionais prevista no <strong data-start=\"747\" data-end=\"766\">GRO\/PGR da NR 1<\/strong>.<\/p>\n<p data-start=\"769\" data-end=\"827\">\ud83d\udc49 Conhe\u00e7a a GNR Ambiental:<br data-start=\"796\" data-end=\"799\" \/><a class=\"decorated-link\" href=\"https:\/\/gnrambiental.com.br\/\" target=\"_new\" rel=\"noopener\" data-start=\"799\" data-end=\"827\">https:\/\/gnrambiental.com.br\/<\/a><\/p>\n<hr data-start=\"829\" data-end=\"832\" \/>\n<h2 data-start=\"834\" data-end=\"868\"><strong data-start=\"837\" data-end=\"868\">Origem e evolu\u00e7\u00e3o da NHO 11<\/strong><\/h2>\n<p data-start=\"870\" data-end=\"1051\">Na d\u00e9cada de 1980, a Fundacentro publicou as <strong data-start=\"915\" data-end=\"954\">Normas de Higiene do Trabalho (NHT)<\/strong>, entre elas a <strong data-start=\"969\" data-end=\"990\">NHT 10-I\/E (1986)<\/strong>, voltada \u00e0 avalia\u00e7\u00e3o ocupacional dos n\u00edveis de iluminamento.<\/p>\n<p data-start=\"1053\" data-end=\"1219\">Com a evolu\u00e7\u00e3o tecnol\u00f3gica dos sistemas de ilumina\u00e7\u00e3o e a necessidade de <strong data-start=\"1126\" data-end=\"1172\">procedimentos mais atualizados e completos<\/strong>, tornou-se necess\u00e1ria a revis\u00e3o dessas normas.<\/p>\n<p data-start=\"1221\" data-end=\"1423\">\ud83d\udccc Em <strong data-start=\"1227\" data-end=\"1235\">2018<\/strong>, foi publicada a <strong data-start=\"1253\" data-end=\"1263\">NHO 11<\/strong>, que <strong data-start=\"1269\" data-end=\"1313\">substitui e atualiza a antiga NHT 10-I\/E<\/strong>, incorporando crit\u00e9rios mais modernos, avalia\u00e7\u00f5es qualitativas e requisitos m\u00ednimos para relat\u00f3rios t\u00e9cnicos.<\/p>\n<hr data-start=\"1425\" data-end=\"1428\" \/>\n<h2 data-start=\"1430\" data-end=\"1462\"><strong data-start=\"1433\" data-end=\"1462\">O que a NHO 11 estabelece<\/strong><\/h2>\n<p data-start=\"1464\" data-end=\"1601\">A <strong data-start=\"1466\" data-end=\"1476\">NHO 11<\/strong> define crit\u00e9rios para avalia\u00e7\u00e3o dos <strong data-start=\"1513\" data-end=\"1545\">n\u00edveis de iluminamento (lux)<\/strong> em diversos tipos de ambientes e atividades, tais como:<\/p>\n<ul data-start=\"1603\" data-end=\"1813\">\n<li data-start=\"1603\" data-end=\"1642\">\n<p data-start=\"1605\" data-end=\"1642\">Escrit\u00f3rios e \u00e1reas administrativas<\/p>\n<\/li>\n<li data-start=\"1643\" data-end=\"1676\">\n<p data-start=\"1645\" data-end=\"1676\">Ind\u00fastrias e \u00e1reas produtivas<\/p>\n<\/li>\n<li data-start=\"1677\" data-end=\"1714\">\n<p data-start=\"1679\" data-end=\"1714\">Hospitais, escolas e laborat\u00f3rios<\/p>\n<\/li>\n<li data-start=\"1715\" data-end=\"1751\">\n<p data-start=\"1717\" data-end=\"1751\">Com\u00e9rcios e \u00e1reas de atendimento<\/p>\n<\/li>\n<li data-start=\"1752\" data-end=\"1781\">\n<p data-start=\"1754\" data-end=\"1781\">Igrejas e locais de culto<\/p>\n<\/li>\n<li data-start=\"1782\" data-end=\"1813\">\n<p data-start=\"1784\" data-end=\"1813\">\u00c1reas de circula\u00e7\u00e3o e apoio<\/p>\n<\/li>\n<\/ul>\n<p data-start=\"1815\" data-end=\"1922\">Al\u00e9m disso, a norma <strong data-start=\"1835\" data-end=\"1898\">auxilia na identifica\u00e7\u00e3o de falhas no sistema de ilumina\u00e7\u00e3o<\/strong> que possam comprometer:<\/p>\n<ul data-start=\"1923\" data-end=\"2006\">\n<li data-start=\"1923\" data-end=\"1953\">\n<p data-start=\"1925\" data-end=\"1953\">A seguran\u00e7a do trabalhador<\/p>\n<\/li>\n<li data-start=\"1954\" data-end=\"1977\">\n<p data-start=\"1956\" data-end=\"1977\">O desempenho visual<\/p>\n<\/li>\n<li data-start=\"1978\" data-end=\"2006\">\n<p data-start=\"1980\" data-end=\"2006\">A efici\u00eancia do trabalho<\/p>\n<\/li>\n<\/ul>\n<hr data-start=\"2008\" data-end=\"2011\" \/>\n<h2 data-start=\"2013\" data-end=\"2076\"><strong data-start=\"2016\" data-end=\"2076\">Principais avan\u00e7os da NHO 11 em rela\u00e7\u00e3o \u00e0 norma anterior<\/strong><\/h2>\n<p data-start=\"2078\" data-end=\"2185\">Entre as principais melhorias trazidas pela <strong data-start=\"2122\" data-end=\"2171\">NHO 11 \u2013 Avalia\u00e7\u00e3o dos n\u00edveis de iluminamento<\/strong>, destacam-se:<\/p>\n<ul data-start=\"2187\" data-end=\"2712\">\n<li data-start=\"2187\" data-end=\"2280\">\n<p data-start=\"2189\" data-end=\"2280\">\ud83d\udcca <strong data-start=\"2192\" data-end=\"2244\">Quadros com n\u00edveis m\u00ednimos de iluminamento (lux)<\/strong> por ambiente, tarefa ou atividade<\/p>\n<\/li>\n<li data-start=\"2281\" data-end=\"2351\">\n<p data-start=\"2283\" data-end=\"2351\">\ud83d\udca1 Considera\u00e7\u00f5es sobre <strong data-start=\"2306\" data-end=\"2349\">tipo de l\u00e2mpada e sistema de ilumina\u00e7\u00e3o<\/strong><\/p>\n<\/li>\n<li data-start=\"2352\" data-end=\"2555\">\n<p data-start=\"2354\" data-end=\"2403\">\ud83d\udc41\ufe0f Avalia\u00e7\u00e3o <strong data-start=\"2368\" data-end=\"2383\">qualitativa<\/strong> de par\u00e2metros como:<\/p>\n<ul data-start=\"2406\" data-end=\"2555\">\n<li data-start=\"2406\" data-end=\"2421\">\n<p data-start=\"2408\" data-end=\"2421\">Ofuscamento<\/p>\n<\/li>\n<li data-start=\"2424\" data-end=\"2438\">\n<p data-start=\"2426\" data-end=\"2438\">Cintila\u00e7\u00e3o<\/p>\n<\/li>\n<li data-start=\"2441\" data-end=\"2466\">\n<p data-start=\"2443\" data-end=\"2466\">Efeito estrobosc\u00f3pico<\/p>\n<\/li>\n<li data-start=\"2469\" data-end=\"2495\">\n<p data-start=\"2471\" data-end=\"2495\">Direcionalidade da luz<\/p>\n<\/li>\n<li data-start=\"2498\" data-end=\"2520\">\n<p data-start=\"2500\" data-end=\"2520\">Sombras excessivas<\/p>\n<\/li>\n<li data-start=\"2523\" data-end=\"2555\">\n<p data-start=\"2525\" data-end=\"2555\">Apar\u00eancia da cor e contraste<\/p>\n<\/li>\n<\/ul>\n<\/li>\n<li data-start=\"2556\" data-end=\"2628\">\n<p data-start=\"2558\" data-end=\"2628\">\ud83d\udcc4 Defini\u00e7\u00e3o de <strong data-start=\"2574\" data-end=\"2626\">conte\u00fado m\u00ednimo obrigat\u00f3rio do relat\u00f3rio t\u00e9cnico<\/strong><\/p>\n<\/li>\n<li data-start=\"2629\" data-end=\"2712\">\n<p data-start=\"2631\" data-end=\"2712\">\u2705 Inclus\u00e3o de <strong data-start=\"2645\" data-end=\"2683\">listas de verifica\u00e7\u00e3o (checklists)<\/strong> para avalia\u00e7\u00e3o do ambiente<\/p>\n<\/li>\n<\/ul>\n<hr data-start=\"2714\" data-end=\"2717\" \/>\n<h2 data-start=\"2719\" data-end=\"2773\"><strong data-start=\"2722\" data-end=\"2773\">N\u00edveis m\u00ednimos de iluminamento segundo a NHO 11<\/strong><\/h2>\n<p data-start=\"2775\" data-end=\"2896\">De acordo com a norma, os ambientes de trabalho devem possuir <strong data-start=\"2837\" data-end=\"2860\">ilumina\u00e7\u00e3o uniforme<\/strong>, adequada \u00e0 atividade desenvolvida.<\/p>\n<p data-start=\"2898\" data-end=\"2923\">\ud83d\udccc Como refer\u00eancia geral:<\/p>\n<ul data-start=\"2924\" data-end=\"3112\">\n<li data-start=\"2924\" data-end=\"3008\">\n<p data-start=\"2926\" data-end=\"3008\">Em \u00e1reas de trabalho cont\u00ednuo, a ilumin\u00e2ncia <strong data-start=\"2971\" data-end=\"3006\">n\u00e3o deve ser inferior a 200 lux<\/strong><\/p>\n<\/li>\n<li data-start=\"3009\" data-end=\"3112\">\n<p data-start=\"3011\" data-end=\"3112\">Quando houver <strong data-start=\"3025\" data-end=\"3051\">ilumina\u00e7\u00e3o suplementar<\/strong>, deve-se verificar tamb\u00e9m o <strong data-start=\"3080\" data-end=\"3100\">entorno imediato<\/strong> da tarefa<\/p>\n<\/li>\n<\/ul>\n<p data-start=\"3114\" data-end=\"3202\">Esses valores variam conforme o tipo de atividade, exig\u00eancia visual e ambiente avaliado.<\/p>\n<hr data-start=\"3204\" data-end=\"3207\" \/>\n<h2 data-start=\"3209\" data-end=\"3264\"><strong data-start=\"3212\" data-end=\"3264\">Avalia\u00e7\u00e3o preliminar e qualitativa da ilumina\u00e7\u00e3o<\/strong><\/h2>\n<p data-start=\"3266\" data-end=\"3406\">A <strong data-start=\"3268\" data-end=\"3278\">NHO 11<\/strong> prev\u00ea uma <strong data-start=\"3289\" data-end=\"3313\">avalia\u00e7\u00e3o preliminar<\/strong>, que analisa aspectos que podem comprometer a seguran\u00e7a e o desempenho do trabalhador, como:<\/p>\n<ul data-start=\"3408\" data-end=\"3560\">\n<li data-start=\"3408\" data-end=\"3443\">\n<p data-start=\"3410\" data-end=\"3443\">Ofuscamento direto ou refletido<\/p>\n<\/li>\n<li data-start=\"3444\" data-end=\"3465\">\n<p data-start=\"3446\" data-end=\"3465\">Cintila\u00e7\u00e3o da luz<\/p>\n<\/li>\n<li data-start=\"3466\" data-end=\"3491\">\n<p data-start=\"3468\" data-end=\"3491\">Efeito estrobosc\u00f3pico<\/p>\n<\/li>\n<li data-start=\"3492\" data-end=\"3514\">\n<p data-start=\"3494\" data-end=\"3514\">Sombras excessivas<\/p>\n<\/li>\n<li data-start=\"3515\" data-end=\"3539\">\n<p data-start=\"3517\" data-end=\"3539\">Contraste inadequado<\/p>\n<\/li>\n<li data-start=\"3540\" data-end=\"3560\">\n<p data-start=\"3542\" data-end=\"3560\">Apar\u00eancia da cor<\/p>\n<\/li>\n<\/ul>\n<p data-start=\"3562\" data-end=\"3683\">Essa etapa \u00e9 fundamental para identificar <strong data-start=\"3604\" data-end=\"3625\">n\u00e3o conformidades<\/strong>, mesmo quando os n\u00edveis de lux aparentam estar adequados.<\/p>\n<hr data-start=\"3685\" data-end=\"3688\" \/>\n<h2 data-start=\"3690\" data-end=\"3732\"><strong data-start=\"3693\" data-end=\"3732\">Manuten\u00e7\u00e3o do sistema de ilumina\u00e7\u00e3o<\/strong><\/h2>\n<p data-start=\"3734\" data-end=\"3851\">Segundo a <strong data-start=\"3744\" data-end=\"3754\">NHO 11<\/strong>, os sistemas de ilumina\u00e7\u00e3o devem passar por <strong data-start=\"3799\" data-end=\"3836\">manuten\u00e7\u00e3o preventiva e corretiva<\/strong>, considerando:<\/p>\n<ul data-start=\"3853\" data-end=\"4008\">\n<li data-start=\"3853\" data-end=\"3878\">\n<p data-start=\"3855\" data-end=\"3878\">Limpeza de lumin\u00e1rias<\/p>\n<\/li>\n<li data-start=\"3879\" data-end=\"3921\">\n<p data-start=\"3881\" data-end=\"3921\">Substitui\u00e7\u00e3o de l\u00e2mpadas e componentes<\/p>\n<\/li>\n<li data-start=\"3922\" data-end=\"3973\">\n<p data-start=\"3924\" data-end=\"3973\">Condi\u00e7\u00f5es ambientais (poeira, umidade, vapores)<\/p>\n<\/li>\n<li data-start=\"3974\" data-end=\"4008\">\n<p data-start=\"3976\" data-end=\"4008\">Tipo de atividade desenvolvida<\/p>\n<\/li>\n<\/ul>\n<p data-start=\"4010\" data-end=\"4113\">A periodicidade da manuten\u00e7\u00e3o varia conforme as caracter\u00edsticas do ambiente e do sistema de ilumina\u00e7\u00e3o.<\/p>\n<hr data-start=\"4115\" data-end=\"4118\" \/>\n<h2 data-start=\"4120\" data-end=\"4169\"><strong data-start=\"4123\" data-end=\"4169\">Consequ\u00eancias de uma ilumina\u00e7\u00e3o inadequada<\/strong><\/h2>\n<p data-start=\"4171\" data-end=\"4220\">A ilumina\u00e7\u00e3o deficiente ou excessiva pode causar:<\/p>\n<ul data-start=\"4222\" data-end=\"4371\">\n<li data-start=\"4222\" data-end=\"4239\">\n<p data-start=\"4224\" data-end=\"4239\">Fadiga visual<\/p>\n<\/li>\n<li data-start=\"4240\" data-end=\"4259\">\n<p data-start=\"4242\" data-end=\"4259\">Dores de cabe\u00e7a<\/p>\n<\/li>\n<li data-start=\"4260\" data-end=\"4287\">\n<p data-start=\"4262\" data-end=\"4287\">Redu\u00e7\u00e3o da concentra\u00e7\u00e3o<\/p>\n<\/li>\n<li data-start=\"4288\" data-end=\"4321\">\n<p data-start=\"4290\" data-end=\"4321\">Aumento de erros operacionais<\/p>\n<\/li>\n<li data-start=\"4322\" data-end=\"4371\">\n<p data-start=\"4324\" data-end=\"4371\">Eleva\u00e7\u00e3o dos \u00edndices de acidentes de trabalho<\/p>\n<\/li>\n<\/ul>\n<p data-start=\"4373\" data-end=\"4547\">\ud83d\udccc Uma ilumina\u00e7\u00e3o inadequada <strong data-start=\"4402\" data-end=\"4442\">n\u00e3o \u00e9 apenas um problema de conforto<\/strong>, mas sim um <strong data-start=\"4455\" data-end=\"4485\">fator de risco ocupacional<\/strong>, impactando diretamente a sa\u00fade e a seguran\u00e7a do trabalhador.<\/p>\n<hr data-start=\"4549\" data-end=\"4552\" \/>\n<h2 data-start=\"4554\" data-end=\"4615\"><strong data-start=\"4557\" data-end=\"4615\">Quando realizar a avalia\u00e7\u00e3o dos n\u00edveis de iluminamento<\/strong><\/h2>\n<p data-start=\"4617\" data-end=\"4711\">A <strong data-start=\"4619\" data-end=\"4650\">avalia\u00e7\u00e3o conforme a NHO 11<\/strong> deve ser realizada <strong data-start=\"4670\" data-end=\"4701\">no pior cen\u00e1rio do ambiente<\/strong>, ou seja:<\/p>\n<ul data-start=\"4713\" data-end=\"4898\">\n<li data-start=\"4713\" data-end=\"4772\">\n<p data-start=\"4715\" data-end=\"4772\">Em turnos diurnos: durante o hor\u00e1rio normal de opera\u00e7\u00e3o<\/p>\n<\/li>\n<li data-start=\"4773\" data-end=\"4898\">\n<p data-start=\"4775\" data-end=\"4898\">Em locais com <strong data-start=\"4789\" data-end=\"4808\">turnos noturnos<\/strong>: a medi\u00e7\u00e3o deve ser feita <strong data-start=\"4835\" data-end=\"4853\">tamb\u00e9m \u00e0 noite<\/strong>, quando n\u00e3o h\u00e1 contribui\u00e7\u00e3o da luz natural<\/p>\n<\/li>\n<\/ul>\n<p data-start=\"4900\" data-end=\"4969\">Isso garante resultados representativos da real condi\u00e7\u00e3o de trabalho.<\/p>\n<hr data-start=\"4971\" data-end=\"4974\" \/>\n<h2 data-start=\"4976\" data-end=\"5039\"><strong data-start=\"4979\" data-end=\"5039\">Import\u00e2ncia da avalia\u00e7\u00e3o de ilumina\u00e7\u00e3o conforme a NHO 11<\/strong><\/h2>\n<p data-start=\"5041\" data-end=\"5075\">Uma boa ilumina\u00e7\u00e3o contribui para:<\/p>\n<ul data-start=\"5076\" data-end=\"5207\">\n<li data-start=\"5076\" data-end=\"5100\">\n<p data-start=\"5078\" data-end=\"5100\">Redu\u00e7\u00e3o de acidentes<\/p>\n<\/li>\n<li data-start=\"5101\" data-end=\"5133\">\n<p data-start=\"5103\" data-end=\"5133\">Melhora do desempenho visual<\/p>\n<\/li>\n<li data-start=\"5134\" data-end=\"5157\">\n<p data-start=\"5136\" data-end=\"5157\">Maior produtividade<\/p>\n<\/li>\n<li data-start=\"5158\" data-end=\"5207\">\n<p data-start=\"5160\" data-end=\"5207\">Atendimento \u00e0s exig\u00eancias legais e normativas<\/p>\n<\/li>\n<\/ul>\n<p data-start=\"5209\" data-end=\"5266\">A avalia\u00e7\u00e3o de iluminamento \u00e9 frequentemente integrada a:<\/p>\n<ul data-start=\"5267\" data-end=\"5439\">\n<li data-start=\"5267\" data-end=\"5350\">\n<p data-start=\"5269\" data-end=\"5350\"><strong data-start=\"5269\" data-end=\"5295\">Laudo de Insalubridade<\/strong><br data-start=\"5295\" data-end=\"5298\" \/><a class=\"decorated-link\" href=\"https:\/\/gnrambiental.com.br\/laudo-de-insalubridade\" target=\"_new\" rel=\"noopener\" data-start=\"5298\" data-end=\"5348\">https:\/\/gnrambiental.com.br\/laudo-de-insalubridade<\/a><\/p>\n<\/li>\n<li data-start=\"5352\" data-end=\"5439\">\n<p data-start=\"5354\" data-end=\"5439\"><strong data-start=\"5354\" data-end=\"5406\">GRO \/ PGR \u2013 Gerenciamento de Riscos Ocupacionais<\/strong><br data-start=\"5406\" data-end=\"5409\" \/><a class=\"decorated-link\" href=\"https:\/\/gnrambiental.com.br\/\" target=\"_new\" rel=\"noopener\" data-start=\"5409\" data-end=\"5437\">https:\/\/gnrambiental.com.br\/<\/a><\/p>\n<\/li>\n<\/ul>\n<hr data-start=\"5441\" data-end=\"5444\" \/>\n<h2 data-start=\"5446\" data-end=\"5498\"><strong data-start=\"5449\" data-end=\"5498\">Avalia\u00e7\u00e3o de iluminamento com a GNR Ambiental<\/strong><\/h2>\n<p data-start=\"5500\" data-end=\"5582\">A <strong data-start=\"5502\" data-end=\"5519\">GNR Ambiental<\/strong> realiza <strong data-start=\"5528\" data-end=\"5576\">avalia\u00e7\u00f5es de iluminamento conforme a NHO 11<\/strong>, com:<\/p>\n<p data-start=\"5584\" data-end=\"5755\">\u2714 Profissionais qualificados<br data-start=\"5612\" data-end=\"5615\" \/>\u2714 Relat\u00f3rios t\u00e9cnicos completos<br data-start=\"5646\" data-end=\"5649\" \/>\u2714 Integra\u00e7\u00e3o com laudos de SST<br data-start=\"5679\" data-end=\"5682\" \/>\u2714 Atendimento a auditorias e per\u00edcias<br data-start=\"5719\" data-end=\"5722\" \/>\u2714 Suporte t\u00e9cnico especializado<\/p>\n<p data-start=\"5757\" data-end=\"5824\">\ud83d\udd17 Conhe\u00e7a todos os nossos servi\u00e7os:<br data-start=\"5793\" data-end=\"5796\" \/><a class=\"decorated-link\" href=\"https:\/\/gnrambiental.com.br\/\" target=\"_new\" rel=\"noopener\" data-start=\"5796\" data-end=\"5824\">https:\/\/gnrambiental.com.br\/<\/a><\/p>\n<hr data-start=\"5826\" data-end=\"5829\" \/>\n<h2 data-start=\"5831\" data-end=\"5862\"><strong data-start=\"5834\" data-end=\"5862\">Fale com a GNR Ambiental<\/strong><\/h2>\n<p data-start=\"5864\" data-end=\"5957\">\ud83d\udcde (11) 2374-1201<br data-start=\"5881\" data-end=\"5884\" \/>\ud83d\udcf1 (11) 97285-9101<br data-start=\"5902\" data-end=\"5905\" \/>\ud83d\udcf1 (11) 95277-2125<br data-start=\"5923\" data-end=\"5926\" \/>\ud83c\udf10 <a class=\"decorated-link\" href=\"https:\/\/gnrambiental.com.br\/\" target=\"_new\" rel=\"noopener\" data-start=\"5929\" data-end=\"5957\">https:\/\/gnrambiental.com.br\/<\/a><\/p>\n<p data-start=\"5959\" data-end=\"6051\"><strong data-start=\"5959\" data-end=\"6051\">GNR Ambiental \u2013 Higiene ocupacional, seguran\u00e7a e conformidade t\u00e9cnica com credibilidade.<\/strong><\/p>\n","protected":false},"excerpt":{"rendered":"<p>A NHO 11 \u2013 Avalia\u00e7\u00e3o dos n\u00edveis de iluminamento em ambientes internos de trabalho \u00e9 a norma t\u00e9cnica da Fundacentro que estabelece crit\u00e9rios e procedimentos para avaliar a ilumina\u00e7\u00e3o adequada nos ambientes de trabalho, com foco em seguran\u00e7a, sa\u00fade ocupacional e desempenho das atividades. Essa norma \u00e9 amplamente utilizada em avalia\u00e7\u00f5es de higiene ocupacional, laudos [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":371,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_et_pb_use_builder":"off","_et_pb_old_content":"","_et_gb_content_width":"","_joinchat":[],"footnotes":""},"categories":[6,4],"tags":[91,76,59,28,89,88,90,39],"class_list":["post-370","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-consultoria","category-seguranca-do-trabalho","tag-avaliacao-cupacional","tag-engenharia-ambiental","tag-gnr","tag-gnr-ambiental","tag-iluminamento","tag-nho-11","tag-normas-de-higiene","tag-seguranca-do-trabalho"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v24.6 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>NHO 11 \u2013 Avalia\u00e7\u00e3o dos N\u00edveis de Iluminamento em Ambientes Internos de Trabalho - GNR Ambiental<\/title>\n<meta name=\"description\" content=\"A Coordena\u00e7\u00e3o de Higiene do Trabalho da Funda\u00e7\u00e3o Jorge Duprat Figueiredo de Seguran\u00e7a e Medicina do Trabalho (Fundacentro) publicou de uma s\u00e9rie de normas t\u00e9cnicas denominadas Normas de Higiene do Trabalho (NHT) na d\u00e9cada de 80. Com isso, foi apresentado a NHT 10-I\/E \u2013 Norma para avalia\u00e7\u00e3o ocupacional do n\u00edvel de iluminamento.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/gnrambiental.com.br\/noticias\/nho-11-avaliacao-dos-niveis-de-iluminamento-em-ambientes-internos-de-trabalho\/\" \/>\n<meta property=\"og:locale\" content=\"pt_BR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"NHO 11 \u2013 Avalia\u00e7\u00e3o dos N\u00edveis de Iluminamento em Ambientes Internos de Trabalho - GNR Ambiental\" \/>\n<meta property=\"og:description\" content=\"A Coordena\u00e7\u00e3o de Higiene do Trabalho da Funda\u00e7\u00e3o Jorge Duprat Figueiredo de Seguran\u00e7a e Medicina do Trabalho (Fundacentro) publicou de uma s\u00e9rie de normas t\u00e9cnicas denominadas Normas de Higiene do Trabalho (NHT) na d\u00e9cada de 80. Com isso, foi apresentado a NHT 10-I\/E \u2013 Norma para avalia\u00e7\u00e3o ocupacional do n\u00edvel de iluminamento.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/gnrambiental.com.br\/noticias\/nho-11-avaliacao-dos-niveis-de-iluminamento-em-ambientes-internos-de-trabalho\/\" \/>\n<meta property=\"og:site_name\" content=\"GNR Ambiental\" \/>\n<meta property=\"article:published_time\" content=\"2020-11-24T16:06:06+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-12-15T20:08:07+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/gnrambiental.com.br\/noticias\/wp-content\/uploads\/2020\/11\/Blog-15.png\" \/>\n\t<meta property=\"og:image:width\" content=\"1080\" \/>\n\t<meta property=\"og:image:height\" content=\"675\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"blog_gnr\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Escrito por\" \/>\n\t<meta name=\"twitter:data1\" content=\"blog_gnr\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. tempo de leitura\" \/>\n\t<meta name=\"twitter:data2\" content=\"5 minutos\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/gnrambiental.com.br\/noticias\/nho-11-avaliacao-dos-niveis-de-iluminamento-em-ambientes-internos-de-trabalho\/\",\"url\":\"https:\/\/gnrambiental.com.br\/noticias\/nho-11-avaliacao-dos-niveis-de-iluminamento-em-ambientes-internos-de-trabalho\/\",\"name\":\"NHO 11 \u2013 Avalia\u00e7\u00e3o dos N\u00edveis de Iluminamento em Ambientes Internos de Trabalho - GNR Ambiental\",\"isPartOf\":{\"@id\":\"https:\/\/gnrambiental.com.br\/noticias\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/gnrambiental.com.br\/noticias\/nho-11-avaliacao-dos-niveis-de-iluminamento-em-ambientes-internos-de-trabalho\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/gnrambiental.com.br\/noticias\/nho-11-avaliacao-dos-niveis-de-iluminamento-em-ambientes-internos-de-trabalho\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/gnrambiental.com.br\/noticias\/wp-content\/uploads\/2020\/11\/Blog-15.png\",\"datePublished\":\"2020-11-24T16:06:06+00:00\",\"dateModified\":\"2025-12-15T20:08:07+00:00\",\"author\":{\"@id\":\"https:\/\/gnrambiental.com.br\/noticias\/#\/schema\/person\/665c9a349aa30972fa8d07edc2ee38af\"},\"description\":\"A Coordena\u00e7\u00e3o de Higiene do Trabalho da Funda\u00e7\u00e3o Jorge Duprat Figueiredo de Seguran\u00e7a e Medicina do Trabalho (Fundacentro) publicou de uma s\u00e9rie de normas t\u00e9cnicas denominadas Normas de Higiene do Trabalho (NHT) na d\u00e9cada de 80. Com isso, foi apresentado a NHT 10-I\/E \u2013 Norma para avalia\u00e7\u00e3o ocupacional do n\u00edvel de iluminamento.\",\"breadcrumb\":{\"@id\":\"https:\/\/gnrambiental.com.br\/noticias\/nho-11-avaliacao-dos-niveis-de-iluminamento-em-ambientes-internos-de-trabalho\/#breadcrumb\"},\"inLanguage\":\"pt-BR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/gnrambiental.com.br\/noticias\/nho-11-avaliacao-dos-niveis-de-iluminamento-em-ambientes-internos-de-trabalho\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"pt-BR\",\"@id\":\"https:\/\/gnrambiental.com.br\/noticias\/nho-11-avaliacao-dos-niveis-de-iluminamento-em-ambientes-internos-de-trabalho\/#primaryimage\",\"url\":\"https:\/\/gnrambiental.com.br\/noticias\/wp-content\/uploads\/2020\/11\/Blog-15.png\",\"contentUrl\":\"https:\/\/gnrambiental.com.br\/noticias\/wp-content\/uploads\/2020\/11\/Blog-15.png\",\"width\":1080,\"height\":675},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/gnrambiental.com.br\/noticias\/nho-11-avaliacao-dos-niveis-de-iluminamento-em-ambientes-internos-de-trabalho\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"In\u00edcio\",\"item\":\"https:\/\/gnrambiental.com.br\/noticias\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"NHO 11 \u2013 Avalia\u00e7\u00e3o dos N\u00edveis de Iluminamento em Ambientes Internos de Trabalho\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/gnrambiental.com.br\/noticias\/#website\",\"url\":\"https:\/\/gnrambiental.com.br\/noticias\/\",\"name\":\"GNR Ambiental\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/gnrambiental.com.br\/noticias\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"pt-BR\"},{\"@type\":\"Person\",\"@id\":\"https:\/\/gnrambiental.com.br\/noticias\/#\/schema\/person\/665c9a349aa30972fa8d07edc2ee38af\",\"name\":\"blog_gnr\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"pt-BR\",\"@id\":\"https:\/\/gnrambiental.com.br\/noticias\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/e4c10858129539ef55035c1f4f80f9c3?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/e4c10858129539ef55035c1f4f80f9c3?s=96&d=mm&r=g\",\"caption\":\"blog_gnr\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"NHO 11 \u2013 Avalia\u00e7\u00e3o dos N\u00edveis de Iluminamento em Ambientes Internos de Trabalho - GNR Ambiental","description":"A Coordena\u00e7\u00e3o de Higiene do Trabalho da Funda\u00e7\u00e3o Jorge Duprat Figueiredo de Seguran\u00e7a e Medicina do Trabalho (Fundacentro) publicou de uma s\u00e9rie de normas t\u00e9cnicas denominadas Normas de Higiene do Trabalho (NHT) na d\u00e9cada de 80. Com isso, foi apresentado a NHT 10-I\/E \u2013 Norma para avalia\u00e7\u00e3o ocupacional do n\u00edvel de iluminamento.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/gnrambiental.com.br\/noticias\/nho-11-avaliacao-dos-niveis-de-iluminamento-em-ambientes-internos-de-trabalho\/","og_locale":"pt_BR","og_type":"article","og_title":"NHO 11 \u2013 Avalia\u00e7\u00e3o dos N\u00edveis de Iluminamento em Ambientes Internos de Trabalho - GNR Ambiental","og_description":"A Coordena\u00e7\u00e3o de Higiene do Trabalho da Funda\u00e7\u00e3o Jorge Duprat Figueiredo de Seguran\u00e7a e Medicina do Trabalho (Fundacentro) publicou de uma s\u00e9rie de normas t\u00e9cnicas denominadas Normas de Higiene do Trabalho (NHT) na d\u00e9cada de 80. Com isso, foi apresentado a NHT 10-I\/E \u2013 Norma para avalia\u00e7\u00e3o ocupacional do n\u00edvel de iluminamento.","og_url":"https:\/\/gnrambiental.com.br\/noticias\/nho-11-avaliacao-dos-niveis-de-iluminamento-em-ambientes-internos-de-trabalho\/","og_site_name":"GNR Ambiental","article_published_time":"2020-11-24T16:06:06+00:00","article_modified_time":"2025-12-15T20:08:07+00:00","og_image":[{"width":1080,"height":675,"url":"https:\/\/gnrambiental.com.br\/noticias\/wp-content\/uploads\/2020\/11\/Blog-15.png","type":"image\/png"}],"author":"blog_gnr","twitter_card":"summary_large_image","twitter_misc":{"Escrito por":"blog_gnr","Est. tempo de leitura":"5 minutos"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/gnrambiental.com.br\/noticias\/nho-11-avaliacao-dos-niveis-de-iluminamento-em-ambientes-internos-de-trabalho\/","url":"https:\/\/gnrambiental.com.br\/noticias\/nho-11-avaliacao-dos-niveis-de-iluminamento-em-ambientes-internos-de-trabalho\/","name":"NHO 11 \u2013 Avalia\u00e7\u00e3o dos N\u00edveis de Iluminamento em Ambientes Internos de Trabalho - GNR Ambiental","isPartOf":{"@id":"https:\/\/gnrambiental.com.br\/noticias\/#website"},"primaryImageOfPage":{"@id":"https:\/\/gnrambiental.com.br\/noticias\/nho-11-avaliacao-dos-niveis-de-iluminamento-em-ambientes-internos-de-trabalho\/#primaryimage"},"image":{"@id":"https:\/\/gnrambiental.com.br\/noticias\/nho-11-avaliacao-dos-niveis-de-iluminamento-em-ambientes-internos-de-trabalho\/#primaryimage"},"thumbnailUrl":"https:\/\/gnrambiental.com.br\/noticias\/wp-content\/uploads\/2020\/11\/Blog-15.png","datePublished":"2020-11-24T16:06:06+00:00","dateModified":"2025-12-15T20:08:07+00:00","author":{"@id":"https:\/\/gnrambiental.com.br\/noticias\/#\/schema\/person\/665c9a349aa30972fa8d07edc2ee38af"},"description":"A Coordena\u00e7\u00e3o de Higiene do Trabalho da Funda\u00e7\u00e3o Jorge Duprat Figueiredo de Seguran\u00e7a e Medicina do Trabalho (Fundacentro) publicou de uma s\u00e9rie de normas t\u00e9cnicas denominadas Normas de Higiene do Trabalho (NHT) na d\u00e9cada de 80. Com isso, foi apresentado a NHT 10-I\/E \u2013 Norma para avalia\u00e7\u00e3o ocupacional do n\u00edvel de iluminamento.","breadcrumb":{"@id":"https:\/\/gnrambiental.com.br\/noticias\/nho-11-avaliacao-dos-niveis-de-iluminamento-em-ambientes-internos-de-trabalho\/#breadcrumb"},"inLanguage":"pt-BR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/gnrambiental.com.br\/noticias\/nho-11-avaliacao-dos-niveis-de-iluminamento-em-ambientes-internos-de-trabalho\/"]}]},{"@type":"ImageObject","inLanguage":"pt-BR","@id":"https:\/\/gnrambiental.com.br\/noticias\/nho-11-avaliacao-dos-niveis-de-iluminamento-em-ambientes-internos-de-trabalho\/#primaryimage","url":"https:\/\/gnrambiental.com.br\/noticias\/wp-content\/uploads\/2020\/11\/Blog-15.png","contentUrl":"https:\/\/gnrambiental.com.br\/noticias\/wp-content\/uploads\/2020\/11\/Blog-15.png","width":1080,"height":675},{"@type":"BreadcrumbList","@id":"https:\/\/gnrambiental.com.br\/noticias\/nho-11-avaliacao-dos-niveis-de-iluminamento-em-ambientes-internos-de-trabalho\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"In\u00edcio","item":"https:\/\/gnrambiental.com.br\/noticias\/"},{"@type":"ListItem","position":2,"name":"NHO 11 \u2013 Avalia\u00e7\u00e3o dos N\u00edveis de Iluminamento em Ambientes Internos de Trabalho"}]},{"@type":"WebSite","@id":"https:\/\/gnrambiental.com.br\/noticias\/#website","url":"https:\/\/gnrambiental.com.br\/noticias\/","name":"GNR Ambiental","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/gnrambiental.com.br\/noticias\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"pt-BR"},{"@type":"Person","@id":"https:\/\/gnrambiental.com.br\/noticias\/#\/schema\/person\/665c9a349aa30972fa8d07edc2ee38af","name":"blog_gnr","image":{"@type":"ImageObject","inLanguage":"pt-BR","@id":"https:\/\/gnrambiental.com.br\/noticias\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/e4c10858129539ef55035c1f4f80f9c3?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/e4c10858129539ef55035c1f4f80f9c3?s=96&d=mm&r=g","caption":"blog_gnr"}}]}},"_links":{"self":[{"href":"https:\/\/gnrambiental.com.br\/noticias\/wp-json\/wp\/v2\/posts\/370"}],"collection":[{"href":"https:\/\/gnrambiental.com.br\/noticias\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/gnrambiental.com.br\/noticias\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/gnrambiental.com.br\/noticias\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/gnrambiental.com.br\/noticias\/wp-json\/wp\/v2\/comments?post=370"}],"version-history":[{"count":2,"href":"https:\/\/gnrambiental.com.br\/noticias\/wp-json\/wp\/v2\/posts\/370\/revisions"}],"predecessor-version":[{"id":2116,"href":"https:\/\/gnrambiental.com.br\/noticias\/wp-json\/wp\/v2\/posts\/370\/revisions\/2116"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/gnrambiental.com.br\/noticias\/wp-json\/wp\/v2\/media\/371"}],"wp:attachment":[{"href":"https:\/\/gnrambiental.com.br\/noticias\/wp-json\/wp\/v2\/media?parent=370"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/gnrambiental.com.br\/noticias\/wp-json\/wp\/v2\/categories?post=370"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/gnrambiental.com.br\/noticias\/wp-json\/wp\/v2\/tags?post=370"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}